বৃহস্পতিবার, ৩০ নভেম্বর, ২০১৭

বুধবার, ২৯ নভেম্বর, ২০১৭

Fabric faults or defects.

  1. Press off
  2. Run
  3. Scrimps
  4. Boardly
  5. Ladder
  6. Tucking
  7. Float
  8. Missing plush loop
  9. Stain
  10. Thin yarn
  11. Thick yarn
  12. Barre
  13. Holes in fabric
  14. Spariality
  15. Tight loops
  16. Slack loop
  17. Slack loop
  18. Snagging in ladies suits
  19. Bird’s eye
  20. Dropped stitch
  21. Needle line
  22. Bowing
  23. Streak or stop mark
  24. Skewing
  25. Slub

Main parts of jet dyeing machine

1. Main vessel or chamber.
2. Nozzle.
3. Reverse tank
4. Winch roller or reel.
5. Fabric plaiter.
6. Heat Exchanger.
7. Controlling unit or processor.
8. Chemical dosing tanl.
9. Utility Lines.......such as water line, steam inlet e.t.c.
10. Motor & valves. 💚💙

সোমবার, ২৭ নভেম্বর, ২০১৭

Dyeing lab (SOP)

       
                Standard Operating Procedure
               Laboratory-Karooni Knit Composite Ltd
                                                        Ratapur, Safipur, Kaliakoir, Gazipur
Standard Operating Procedure (SOP) Spectra Photometer


·        Name of  Equipment         :-Spectra photometer 
·        Manufacturer                     :-Data color
·        Model                                    :-Datacolor-600
·        Serial Number                     :-10243
·        Room temp                          :-20C/+-2
·        Humanity                             :- 65%/+-2

The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Open the software DCM Match & QC Color Tools.
v Start the Calibration for spectrophotometer every 8 hours.
v UV Calibration for spectrophotometer every week. 

Working Purpose
·        DCI Match-use for Recipe & Dye Color Combination & Check Mesmerism index & others parameter.
·        Color Tools-use for QC check CMC, CIE, pass, fail, Evaluation of color staining & Change in Color.  Q-Tex Value Import/Export & others parameter.

                                                               






Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.
                                                   
 Standard Operating Procedure (SOP) for Dimensional Template:


·        Name of  Equipment         :-Dimensional shrinkage Template
·         
·        Manufacturer                     :-James H Heal
·        Model                                    :-N/P
·        Serial Number                     :-N/P
·        Grading temp                      :N/A



The Following steps are involved to operate the machine:
v Clean the shrinkage Template before the marking


Working Purpose
·        Dimensional Stability measurement (Length & Width). 
















Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

   
                     Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.

  Standard Operating Procedure (SOP) for Electric Balance


·       Name of  Equipment   :-Electric Balance
·       Manufacturer               :-A&D , Korea
·       Model                           :-FSH
·       Capacity(gm.)               :-0.0001 to 300gm





The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the weight.
v Connect the power and switch on the machine.
v Auto calibration.
v Open the door and weight the sample.
v  Switch off and disconnect the power off the machine.


Working Purpose
·        Weight Dyes, salt, soda, fabrics.
·        Weight all liquid chemical








Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                     Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.

  Standard Operating Procedure (SOP) for Electric Balance


·       Name of  Equipment   :-Electric Balance
·       Manufacturer               :-Shemadzu , Japan
·       Model                           :-TX-323L
·       Capacity(gm.)               :-0.001 to 320gm



The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the weight.
v Connect the power and switch on the machine.
v Auto calibration.
v Open the door and weight the sample.
v  Switch off and disconnect the power off the machine.


Working Purpose
·        Weight Dyes, salt, soda, fabrics.
·        Weight all liquid chemical












Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA


                              Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd.
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.
                                                   

Standard Operating Procedure (SOP) for Incubator:


·        Name of  Equipment         :-Incubator
·        Manufacturer                     :-SDL Atlas, England
·        Model                                    :-G 209 A
·        Grading temp                      :Preheater



The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set the temperature as per requirement by pressing the digit…….and digit
v Save the set up temperature by pressing the scroll.
v Timers switch on and set the time as per requirement.
v Prepared the Sample as per method.
v Open the door and enter the sample into the machine.
v After complete the time & out the specimen and evaluate as per method.
v  Switch off the heater and disconnect the power off the machine.
Working Purpose
·        Colour Fastness to Water
·        Colour Fastness to Perspiration
·        Colour Fastness Phenolic Yellowing
·        Colour Fastness Saliva




Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA


                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                    Ratanpur, Safipur , Kaliakoir,Gazipur.


                 Standard Operating Procedure (SOP) for Rota wash:

·        Name of  Equipment        :-Rota wash Color Fastness Machine
·        Manufacturer                    :-SDL Atlas
·        Model                                  :- M228 B
·        Grading temp                    :- 2C/minute



     The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set the temperature as per requirement by pressing the digit…….and digit
v Save the set up temperature by pressing the scroll.
v Heater on by pressing the button.
v Timers switch on and set the time as per requirement.
v Prepared the Sample as per method.
v Open the door and enter the sample into the machine.
v The start the test by on the rotor drive button.
v After complete the cycle take out the specimen and evaluate as per method.
v  Switch off the heater, Timer, Rotor drive and disconnect the power off the machine.

Working Purpose
·        Color Fastness to Washing











Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                      Standard Operating Procedure
                    Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.




     Standard Operating Procedure (SOP) for Crock Meter:

·        Name of  Equipment         :-Crock Meter
·        Manufacturer                     :-SDL Atlas, England
·        Model                                    :-M 238 AA
·        Serial Number                     :-708C0057



The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set the Cycle as per requirement by pressing the digit…….and digit
v Prepared the Sample as per method.
v After complete the cycle take out the specimen and evaluate as per method.
v  Switch off and disconnect the power off the machine.

Working Purpose
·        Colour Fastness to Dry & Wet Rubbing












Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA


                      Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir,Gazipur.

          Standard Operating Procedure(SOP)for Siemens Dryer:


·        Name of  Equipment         :-Trumble Dryer Machine
·        Manufacturer                     :-Siemens
·        Model                                    :- WT 44C101GC
·        Temperature                       :-Low- 50C,Medium-60C,High-70C



The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set & Save  the Dry temperature as per requirement by pressing the digit…….and digit
v Open the door and loading the sample run the program.
v End the  program unload the specimen and relax to condition & evaluate as per method.
v  Switch off the machine and disconnect the power off the machine.

Working Purpose
·        Dimensional Stability to household laundering
·        Twisting 
·        Appearance after wash 
·        Print Durability









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir,Gazipur.

          Standard Operating Procedure(SOP)for Electrolux Dryer:


·        Name of  Equipment         :-Trumble Dryer Machine
·        Manufacturer                     :-Electrolux , Sweden.
·        Model                                    :- T 5130
·        Temperature                       :-Low- 50C,Medium-60C,High-70C



The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set & Save  the Dry temperature as per requirement by pressing the digit…….and digit
v Open the door and loading the sample run the program.
v End the  program unload the specimen and relax to condition & evaluate as per method.
v  Switch off the machine and disconnect the power off the machine.

Working Purpose
·        Dimensional Stability to household laundering
·        Twisting 
·        Appearance after wash 
·        Print Durability









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur,Kaliakoir,Gazipur.


         Standard Operating Procedure(SOP)for Siemens Washing:

·        Name of  Equipment         :-Washing Machine
·        Manufacturer                     :-Siemens
·        Model                                    :- WM08E161ME
·        Speed                                                :-800 rpm


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set & Save  the washing program temperature as per requirement by pressing the digit…….and digit
v Open the door and loading  the sample run the program.
v Loading weight at least 2.0 kgs in this machine.
v End the  program unload the specimen and evaluate as per method.
v  Switch off the machine and disconnect the power off the machine.

Working Purpose
·        Dimensional Stability to household laundering
·        Colour Fastness to household laundering
·        Twisting
·        Appearance after wash 
·        Print Durability







Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA


                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur,Kaliakoir,Gazipur.


         Standard Operating Procedure(SOP)for Panasonic Washing:

·        Name of  Equipment         :-Washing Machine
·        Manufacturer                     :-Panasonic , Japan
·        Model                                    :- NA 2783659301
·        Speed                                                :- 1200 rpm


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set & Save  the washing program temperature as per requirement by pressing the digit…….and digit
v Open the door and loading  the sample run the program.
v Loading weight at least 2.0 kgs in this machine.
v End the  program unload the specimen and evaluate as per method.
v  Switch off the machine and disconnect the power off the machine.

Working Purpose
·        Dimensional Stability to household laundering
·        Colour Fastness to household laundering
·        Twisting
·        Appearance after wash 
·        Print Durability








Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur,Kaliakoir,Gazipur.


         Standard Operating Procedure(SOP)for Electrolux Washing:

·        Name of  Equipment         :-Washing Machine
·        Manufacturer                     :- Electrolux , Thailand
·        Model                                    :- W555H
·        Speed                                                :- 1400 rpm


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set & Save  the washing program temperature as per requirement by pressing the digit…….and digit
v Open the door and loading  the sample run the program.
v Loading weight at least 2.0 kgs in this machine.
v End the  program unload the specimen and evaluate as per method.
v  Switch off the machine and disconnect the power off the machine.

Working Purpose
·        Dimensional Stability to household laundering
·        Colour Fastness to household laundering
·        Twisting
·        Appearance after wash 
·        Print Durability










Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur,Kaliakoir,Gazipur.


         Standard Operating Procedure(SOP)for Electrolux Washing:

·        Name of  Equipment         :-Washing Machine
·        Manufacturer                     :- Electrolux , Thailand
·        Model                                    :- W455H
·        Speed                                                :- 1400 rpm


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set & Save  the washing program temperature as per requirement by pressing the digit…….and digit
v Open the door and loading  the sample run the program.
v Loading weight at least 2.0 kgs in this machine.
v End the  program unload the specimen and evaluate as per method.
v  Switch off the machine and disconnect the power off the machine.

Working Purpose
·        Dimensional Stability to household laundering
·        Colour Fastness to household laundering
·        Twisting
·        Appearance after wash 
·        Print Durability









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                    Standard Operating Procedure
                    Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.


       Standard Operating Procedure(SOP)for Lab Ratator:

·        Name of  Equipment         :-Lab Ratator
·        Manufacturer                     :- MCI Electronics, England
·        Model                                    :- RDD-750






The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the Solution.
v Connect the power and switch on the machine.
v Set the Cycle as per requirement by pressing the digit…….and digit
v Prepared the Solution as per method.
v After complete the cycle take out the specimen and evaluate as per method.
v  Switch off and disconnect the power off the machine.

Working Purpose
·        Colour Fastness to wash solution.














Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                     Standard Operating Procedure
                    Laboratory-Karooni Knit Composite Ltd
                                                        Ratanopur, Safipur, Kaliakoir, Gazipur.


       Standard Operating Procedure(SOP)for ICI Pilling:

·        Name of  Equipment         :- ICI Pilling Machine
·        Manufacturer                     :- SDL Atlas, England
·        Model                                    :- M227
·        Cycles                                    :-ISO-14400/7200
·        Speed                                                :-60rpm


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v Connect the power and switch on the machine.
v Set the Cycle as per requirement by pressing the digit…….and digit
v Timers on and set the Cycle as per requirement.
v Prepared the Sample as per method.
v After complete the cycle & Run time take out the specimen and evaluate as per method.
v Switch off and disconnect the power off the machine.

Working Purpose
·        All Viscose Fabrics Test
·        All CVC Fabrics Test
·        All PC Fabrics Test









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                       Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur,Kaliakoir,Gazipur.

         Standard Operating Procedure(SOP)for pH meter:


·        Name of  Equipment         :-pH meter  
·        Manufacturer                     :-Mettler Toledo
·        Model                                    :- S 210
·        Serial Number                     :-6302813




     The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the test.
v  Power button click open the pH meter.
v pH meter Calibration  before reading
v  After finish the work than power off the pH meter.

Working Purpose
·        Check pH such as Salt, Soda, water, perspiration etc.











Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production OfficerQA



                     Standard Operating Procedure
                    Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.


       Standard Operating Procedure(SOP)for Pilling Viewer:

·        Name of  Equipment         :-Pilling Viewer
·        Manufacturer                     :-Verivide
·        Model                                    :-Pilliscope
·        Serial Number                     :-E11835-01




The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the Grading .
v Connect the power and switch on the machine.
v Grading assessment in dark room
v After complete the grading assessment & take out the specimen and evaluate as per method.
v  Switch off and disconnect the power off the machine.

Working Purpose
·        Pilling assessment viewer.













Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA


                        Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.
                                                  

Standard Operating Procedure (SOP) for Verivide Light Box:


·        Name of  Equipment         :-Colour Assessment Cabinet(Light Box)
·        Manufacturer                     :-Verivide
·        Model                                    :-CAC 150 A
·        Serial Number                     :-51330102



The Following steps are involved to operate the machine:
v Clean the Light Box before colour assessment.
v Connect the power and switch on the light box.
v Difference Light & Difference Button.
v D-65 Verivide for artificial Day light primary source.
v TL-83/84 Philips for Shop light primary source.
v  
v UV Sylvania for ultraviolet secondary source.
v F N/P for Filament secondary source.


Working Purpose
·        Visually Colour Assessment. 
·        Colour Hue & Metamarism check.
·        All Colour Fastness to Change & staining grading. 
·        OBA Check.








Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                    Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.
                                                   

Standard Operating Procedure(SOP)for Perspirometer:


·        Name of  Equipment         :-Perspirometer
·        Manufacturer                     :-James H Heal
·        Model                                    :-N/P
·        Serial Number                     :-4529



The Following steps are involved to operate the machine:
v Clean the Perspirometer  properly before precedes the test.



Working Purpose
·        Colour Fastness to Water
·        Colour Fastness to Perspiration
·        Colour Fastness Phenolic Yellowing
·        Colour Fastness Saliva













Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
 Production Officer QA


                    Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.
                                                   

Standard Operating Procedure(SOP)for Perspirometer:


·        Name of  Equipment         :-Perspirometer
·        Manufacturer                     :- SDL Atlas, England
·        Model                                    :-N/P
·        Serial Number                     :-M231/PR1



The Following steps are involved to operate the machine:
v Clean the Perspirometer  properly before precedes the test.



Working Purpose
·        Colour Fastness to Water
·        Colour Fastness to Perspiration
·        Colour Fastness Phenolic Yellowing
·        Colour Fastness Saliva











Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
 Production Officer QA

                   Standard Operating Procedure
                                              Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.


Standard Operating Procedure (SOP) for Lab Dyeing M/C Rapid:
       
·       Name of  Equipment   :-Lab Dyeing Machine
·       Manufacturer               :-Rapid
·       Model                           :- L 24 C
·       Serial Number              :- 51088
·       Grading temp               :-2C/minute


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the work.
v Connect the power and switch on the machine.
v Set & save the dyeing program temp, time & grading per minute etc.
v Set the program  as per requirement dyeing temperature 
v Open the door and loading sample pot enter the machine & run the program.
v End the program unload the dye sample pot.
v  Switch off disconnect the power off the machine.

Working Purpose
·        All kind of  reactive dyeing
·        All Kind of Turquoise Dyeing









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA




                   Standard Operating Procedure
                                              Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.



Standard Operating Procedure (SOP) for Lab Dyeing M/C Rapid:
       
·       Name of  Equipment   :-Lab Dyeing Machine
·       Manufacturer               :-Rapid
·       Model                           :- L 24 C-1
·       Serial Number              :- 0452
·       Grading temp               :-2C/minute


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the work.
v Connect the power and switch on the machine.
v Set & save the dyeing program temp, time & grading per minute etc.
v Set the program  as per requirement dyeing temperature 
v Open the door and loading sample pot enter the machine & run the program.
v End the program unload the dye sample pot.
v  Switch off disconnect the power off the machine.

Working Purpose
·        All kind of  reactive dyeing
·        All Kind of Turquoise Dyeing




Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA



                   Standard Operating Procedure
                                              Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur, Safipur, Kaliakoir, Gazipur.



Standard Operating Procedure (SOP) for Lab Dyeing M/C Mathis:
       
·       Name of  Equipment   :-Lab Dyeing Machine
·       Manufacturer               :-Mathis
·       Model                           :- SW-24P
·       Serial Number              :- 141087
·       Grading temp               :-2C/minute


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the work.
v Connect the power and switch on the machine.
v Set & save the dyeing program temp, time & grading per minute etc.
v Set the program  as per requirement dyeing temperature 
v Open the door and loading sample pot enter the machine & run the program.
v End the program unload the dye sample pot.
v  Switch off disconnect the power off the machine.

Working Purpose
·        All kind of  reactive dyeing
·        All Kind of Turquoise Dyeing









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA


                   Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur, Kaliakoir,Gazipur.


   Standard Operating Procedure (SOP) for Lab Dyeing M/C SDL Atlas:


·       Name of  Equipment   :-Lab Dyeing Machine
·        Manufacturer               :- SDL Atlas, England
·       Model                           :-SK 13 JW
·       Serial Number              :-515287/2
·       Grading temp               :-2C/minute



The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the work.
v Connect the power and switch on the machine.
v Set & save the dyeing program temp, time & grading per minute etc.
v Set the program  as per requirement dyeing temperature 
v Open the door and loading sample pot enter the machine & run the program.
v End the program unload the dye sample pot.
v  Switch off disconnect the power off the machine.

Working Purpose
·        All kind of  reactive dyeing
·        All Kind of Turquoise Dyeing
·        All Kind of Disperse Dyeing






Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA

                   Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur, Kaliakoir,Gazipur.


   Standard Operating Procedure (SOP) for Lab Dyeing M/C SDL Atlas:


·       Name of  Equipment   :-Lab Dyeing Machine
·        Manufacturer               :- SDL Atlas, England
·       Model                           :-SK 13 JW
·       Serial Number              :-515287/1
·       Grading temp               :-2C/minute


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the work.
v Connect the power and switch on the machine.
v Set & save the dyeing program temp, time & grading per minute etc.
v Set the program  as per requirement dyeing temperature 
v Open the door and loading sample pot enter the machine & run the program.
v End the program unload the dye sample pot.
v  Switch off disconnect the power off the machine.

Working Purpose
·        All kind of  reactive dyeing
·        All Kind of Turquoise Dyeing
·        All Kind of Disperse Dyeing









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA


 
                   Standard Operating Procedure
                      Laboratory-Karooni Knit Composite Ltd
                                                        Ratanpur,Safipur, Kaliakoir,Gazipur.


   Standard Operating Procedure (SOP) for Lab Dyeing M/C Lab Tec:


·       Name of  Equipment   :-Lab Dyeing Machine
·        Manufacturer               :- Lab Tec , Taiwan
·       Model                           :-IR 24 M
·       Serial Number              :- 2595
·       Grading temp               :- 2C/minute


The Following steps are involved to operate the machine:
v Clean the machine properly before precedes the work.
v Connect the power and switch on the machine.
v Set & save the dyeing program temp, time & grading per minute etc.
v Set the program  as per requirement dyeing temperature 
v Open the door and loading sample pot enter the machine & run the program.
v End the program unload the dye sample pot.
v  Switch off disconnect the power off the machine.

Working Purpose
·        All kind of  reactive dyeing
·        All Kind of Turquoise Dyeing
·        All Kind of Disperse Dyeing









Prepared By:
Reviewed and Approved By:
Issue By:
Manager-Lab
General Manager-Dyeing
Production Officer QA



What is uster report?